Vol. 14: The First SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-1)

Vol. 14: The First SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-1)

SeaWiFS Post-Launch Technical Report Series



Citation:

Hooker, S.B., H. Claustre, J. Ras, L. Van Heukelem, J-F. Berthon, C. Targa, D. van der Linde, R. Barlow, and H. Sessions, 2000: The First SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-1). NASA Tech. Memo. 2000--206892, Vol. 14, S.B. Hooker and E.R. Firestone, Eds., NASA Goddard Space Flight Center, Greenbelt, Maryland, 42 pp.

Summary:

Four laboratories, which had contributed to various aspects of SeaWiFS calibration and validation activities, participated in the first SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-1): Horn Point Laboratory (USA), the Joint Research Centre (Italy), the Laboratoire de Physique et Chimie Marines (France), and the Marine and Coastal Management group (South Africa). The analyses of the data are presented in Chapter 1 and the individual methods of the four groups are presented in Chapters 2--5. The average (or overall) conclusions of the round-robin are derived from 12 in situ stations occupied during a cruise in the Mediterranean Sea, although, only 11 stations are used in the analyses. The data set is composed of 12 replicates taken during each sampling opportunity with 3 replicates going to each of the 4 laboratories. The average (or overall) results from the intercomparison of 15 pigments or pigment associations are as follows (in some cases, data subsets that exclude pigments which were not analyzed by all the laboratories, or that had unusually large variances, are used to exclude a variety of problematic pigments): a) the accuracy of the four methods in determining the concentration of total chlorophyll a is 7.9% (one method did not separate mono- and divinyl chlorophyll a, and if the samples containing significant divinyl chlorophyll a concentrations are ignored, the four methods have an accuracy of 6.7%); b) the accuracy in determining the full set of pigments is 19.1%; c) there is a reduction in accuracy of approximately -12.2% for every decade (factor of 10) decrease in concentration (based on a data subset); d) the precision of the four methods using a subset data is 8.6% (6.2% for an edited subset); e) the repeatability of the four methods using the subset data is 9.2% (7.2% for an edited subset); and f) the reproducibility of the four methods using the subset data is 21.3% (15.0% for an edited subset).

Download Volume 14